ANÁLIZA KAPASIDADE SUPORTE RAI BAZE STONE MASONRY RETAINING WALL LIU HUSI DYNAMIC CONE PENETROMETER TEST IHA DIRESAUN PROJETU ESTRADA BAUCAU – VENILALE (STA. 22+400 TO’O STA. 22+460
Login
loginBazeia ba rezultadu kalkulasaun teste DCP ba existing ground stone masonry retaining wall Upgrading and Maintinance of the Baucau – Venilale Highway project, husi sta 22+400 to‟o sta 22+460 iha Gua Hitu Postu administrativu Venilale, hakerek nain hakarak hamosu konkluzaun hanesan tuir mai ne‟e;
1) Teste ho ekipamentu Dynamic Cone Penetrometer hanesan prosesu teste ida ne‟ebé lalais no bele identifika valór CBR ba kamada rai baze iha terrenu.
2) Bazeia ba rezultadu kalkulasaun ne‟ebé mak mensiona iha leten hatudu katak rezultadu teste ba existing ground ba stone masonry retaining wall husi pontus 7 refere preienxe kriteria husi métodu AASHTO 1993 ho espesifikasaun ne‟ebé ho valor CBR>2%.
3) Bainhira rezultadu husi korelasaun DCP-CBR la atinze 2%, hatudu katak teste refere seidauk priense kriteria husi métodu AASHTO 1993, signifika densidade husi rai baze refere presiza aumeta kompaktasaun.